    CipherLab Set Scanner Preferences    
Sets the scanner preferences of a CipherLab Scanner (check CipherLab’s ‘Reader DLL’ Documentation).

Parameters

Laser on Time <numeric>

The time, in miliseconds, that the laser stays turned on.

 
Scan Angle <unquoted string>

The angle, in degrees, of the scanner. The possible values are: 47º, 35º or dynamic.

 
Timeout Between Same Barcode <numeric>

The timeout, in miliseconds, between sucessive scan action of the same barcode.

 
Redundancy Level <unquoted string>

The redundancy level for the CipherLab Scanner. The possible values are: Codabar, MSI, Industrial25, Interleaved 25 must be read twice; All codes must be read twice; All codes must be read twice except Codabar, MSI, Industrial25, Interleaved 25; All codes must be read three times; or dynamic.

 
Trigger Mode <unquoted string>

The trigger mode of the CipherLab Scanner. The possible values are: Laser Moder, Continuous Mode or dynamic.

 
Security Level <unquoted string>

The security level of the CipherLab Scanner. The possible values are: Decode most "in-spec" barcodes, Eliminate most misdecodes, Eliminate misdecodes (if level 1 fails), Eliminate misdecodes (if level 2 fails) or dynamic.


 
Inter Char Gap Size <unquoted string>

Defines the size of the characters gaps. The possible values are: Normal intercharacter gaps, Large intercharacter gaps or dynamic.

     
 

    See also
    Barcode Connect
    Barcode Disconnect
    Barcode Enable
    Barcode Disable
    Barcode Scan
    Barcode Set Enabled Symbologies
    Barcode Get Enabled Symbologies
    Motorola Scan Enum Device
    Motorola Scan Connect
    Motorola Scan Disconnect
    Motorola Scan Enable
    Motorola Scan Disable
    Motorola Scan Barcode
    Motorola Scan Set Enabled Symbologies
    Motorola Scan Get Enabled Symbologies
    Honeywell Scan Connect
    Honeywell Scan Disconnect
    Honeywell Scan Enable
    Honeywell Scan Disable
    Honeywell Scan Barcode
    Honeywell Scan Set Enabled Symbologies
    Honeywell Scan Get Enabled Symbologies
    CipherLab Scan Connect
    CipherLab Scan Disconnect
    CipherLab Get Scanner Type
    CipherLab Reset Scanner
    CipherLab Read Barcode
    CipherLab Set Symbology Options
    Cipherlab Scan Enable
    Cipherlab Scan Disable
    Intermec Scan Enum Device
    Intermec Scan Connect
    Intermec Scan Disconnect
    Intermec Scan Enable
    Intermec Scan Disable
    Intermec Scan Barcode
    Intermec Scan Set Enable
    Intermec Scan Get Enable
    Intermec Scan Send Conf. Command
    Intermec Scan Get Conf. Value
    Unitech Scan Connect
    Unitech Scan Disconnect
    Unitech Scan Enable
    Unitech Scan Disable
    Unitech Scan Barcode
    Psion Scan Connect
    Psion Scan Disconnect
    Psion Scan Enable
    Psion Scan Disable
    Psion Scan Barcode
    Psion Scan Set Property
    Psion Scan Get Property
    Nordic ID Connect
    Nordic ID Disconnect
    Nordic ID Get Value
    Nordic ID Set Value
    Nordic ID Execute
    Baracoda Initialize
    Baracoda Uninitialize
    Baracoda Get Device List
    Baracoda Pair Device
    Baracoda Unpair Device
    Baracoda Is Device Paired
    Baracoda Connect Device
    Baracoda Disconnect Device
    Baracoda Is Device Conn.
    Baracoda Send Acknowledge
    M3 Scan Connect
    M3 Scan Disconnect
    M3 Scan Enable
    M3 Scan Disable
    M3 Scan Barcode
    M3 Scan Set Enabled Symbologies
    M3 Scan Get Enabled Symbologies
    Pidion Scan Connect
    Pidion Scan Disconnect
    Pidion Scan Enable
    Pidion Scan Disable
    Pidion Scan Barcode
    Pidion Scan Set Enable Symbologie
    Pidion Scan Get Enable Symbologie
    Denso Scan Connect
    Denso Scan Disconnect
    Denso Scan Enable
    Denso Scan Disable
    Denso Scan Barcode
    Denso Scan Set Enabled Symbologies
    Denso Scan Get Enabled Symbologies
    PointMobile Scan Connect
    PointMobile Scan Disconnect
    PointMobile Scan Enable
    PointMobile Scan Disable
    PointMobile Scan Barcode
    PointMobile Scan Set Enabled Symbologies
    PointMobile Scan Get Enabled Symbology
    Newland Scan Connect
    Newland Scan Disconnect
    Newland Scan Enable
    Newland Scan Disable
    Newland Scan Barcode
    Newland Scan Set Enabled Symbology
    Newland Scan Get Enabled Symbology
    Samples

     
     