Battery |
|
|
AC Power Status <unquoted string>: the control or variable that saves the status of AC Power. If the terminal is plugged in to the electrical power the value is 1 - Online, if it is charging with an USB cable the value is 2 - Online_USB, if the terminal isn't plugged in to the electrical power the value is 0 - Offline, otherwise the value is -1 - Unknow.
|
|
|
Battery Charge Status <unquoted string>: the control or variable that saves the status of the battery charge. Please see in the notes section the possible values for this parameter.
|
|
|
|
Remaining Battery (%) <unquoted string>: the control or variable that saves the value of the remaining battery in percentage. The value is "0%" to "100%" or "-1 - Unknow".
|
|
|
|
Remaining Battery (s) <unquoted string>: the control or variable that saves the value of the remaining battery in seconds. The value is "0 s" to "999999 s" or "-1 - Unknow".
|
|
|
|
Full Battery Seconds (s) <unquoted string>: the control or variable that saves the value of the full battery in seconds. The value is "0 s" to "999999 s" or "-1 - Unknow".
|
|
|
Voltage |
|
|
Voltage (mV) <unquoted string>: the control or variable that saves the voltage of the battery. The possible values are from "0 mV" to "65,535 mV".
|
|
|
|
Current (mA) <unquoted string>: the control or variable that saves the current of the battery. The possible values are from "-32,768 mA" to "32,767 mA".
|
|
|
|
Average Current (mA) <unquoted string>: the control or variable that saves the average current of the battery. The possible values are from "-32,768 mA" to "32,767 mA".
|
|
|
|
Average Interval (ms) <unquoted string>: the control or variable that saves the time (in miliseconds) of integration used in reporting Average Current
|
|
|
|
Current Consumed (mAH) <unquoted string>: the control or variable that saves the power consumed by the battery. The possible values are from "-32,768 mAH" to "0 mAH".
|
|
|
Others |
|
|
|
Temperature (ºC) <unquoted string>: the control or variable that saves the temperature of the battery. The possible value are from "-3,276.8 ºC" to "3,276.8 ºC".
|
|
|
|
Chemestry <unquoted string>: the control or variable that saves the chemistry of the battery. |
|
|
Backup: the following parameters refer to the Backup Battery. |
|
|
|
Battery Charge Status <unquoted string>: the control or variable that saves the status of the backup battery charge. Please see in the notes section the possible values for this parameter.
|
|
|
|
Remaining Battery (%) <unquoted string>: the control or variable that saves the value of the remaining backup battery in percentage. The value is "0%" to "100%" or "-1 - Unknow".
|
|
|
|
Remaining Battery (s) <unquoted string>: the control or variable that saves the value of the remaining backup battery in seconds. The value is "0 s" to "999999 s" or "-1 - Unknow".
|
|
|
|
Full Battery Seconds (s) <unquoted string>: the control or variable that saves the value of the full backup battery in seconds. The value is "0 s" to "999999 s" or "-1 - Unknow".
|
|
|
|
Voltage (mV) <unquoted string>: the control or variable that saves the voltage of the backup battery. The possible values are from "0 mV" to "65,535 mV".
|